Dahlan, Mohammad and Listyorini, Tri (2018) Analysis of Layout of Disturbances in 20 KV Distribution Channels using Artificial Immune System through Negative Selection. Journal of Advanced Research in Dynamical and Control System, 10 (13). pp. 1604-1612. ISSN 1943-023X
This is the latest version of this item.
PDF (Peer Review)
03 analysis of layout of disturbances in 20 KV Distribution Channels.pdf - Published Version Download (2MB) |
|
PDF (Hasil Turnitin)
03 Turnitin.pdf - Published Version Download (2MB) |
|
Preview |
PDF (Article - International Journal Bereputasi)
03 Jurnal Ilmiah International Bereputasi Revisi.pdf - Published Version Download (2MB) | Preview |
Abstrak
To find out the exact location of the disturbance, so that there is no prolonged blackout on the 20 kV distribution channel, then in the study we aim to find out the location of the disturbances that occur in the electricity distribution system using the Artificial Immune System through Negative Selection. The frequent disruption is a single phase to ground short circuit, two phases to the ground, three phases to the ground, and between phases. In testing the system tested is the time needed for the detection system to generate a detector and the ability to detect short circuit faults. The simulation results show the speed of information delivery time of the disturbance between 0.0051 - 0.0203 seconds, so that there is still enough time to send a signal to the security system to localize the interference. Increasing the speed of sending information on the location of the disturbance makes the repair time faster.
Item Type: | Article |
---|---|
Kata Kunci: | disruption of distribution channels, artificial immune system, negative selection |
Subjects: | Teknologi > Teknik elektro, Teknik Nukllir > Elektronika > Teknik komputer. Perangkat keras komputer Ilmu Murni > Matematika > Komputer elektronik. Ilmu komputer Ilmu Murni > Matematika > Perangkat lunak (software) komputer |
Program Studi: | Fakultas Teknik > S1 Teknik Informatika |
Depositing User: | mrs Tri Listyorini |
Date Deposited: | 10 Aug 2019 05:30 |
Last Modified: | 10 Aug 2019 05:30 |
URI: | http://eprints.umk.ac.id/id/eprint/10994 |
Available Versions of this Item
-
Analysis of Layout of Disturbances in 20 KV Distribution Channels using Artificial Immune System through Negative Selection. (deposited 13 May 2019 05:40)
- Analysis of Layout of Disturbances in 20 KV Distribution Channels using Artificial Immune System through Negative Selection. (deposited 10 Aug 2019 05:30) [Currently Displayed]